1.
PLoS One ; 18(4): e0281257, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37115758

RESUMO

BACKGROUND: Identifying a specific threshold level of SARS-CoV-2 antibodies that confers protection in immunocompromised patients has been very challenging. The aim was to assess the threshold of 264 binding antibody units (BAU)/ml using four different SARS-CoV-2 antibody assays (Abbott, Beckman, Roche, and Siemens) and to establish a new optimal threshold of protection for each of the four antibody assays. METHODS: This study was performed on data retrieved from 69 individuals, who received at least one dose of the Pfizer/BioNTech BNT162b2 or Moderna COVID-19 vaccine (Spikevax) at the Alphabio Laboratory in Marseille, France (European Hospital, Alphabio-Biogroup). The results were compared to the percent inhibition calculated using a functional surrogate of a standardized virus neutralization test (Genscript). RESULTS: Samples from 69 patients were analyzed. For a reference cutoff of 264 BAU/ml, assays showed moderate to good overall concordance with Genscript: 87% concordance for Abbott, 78% for Beckman, 75% for Roche, and 88% for Siemens. Overall concordance increased consistently after applying new thresholds, i.e., 148 BAU/ml (Abbott), 48 (Beckman), 559 (Roche), and 270 (Siemens). CONCLUSION: We suggest specific adjusted thresholds (BAU/ml) for the four commercial antibody assays that are used to assess pre-exposure prophylaxis in immunocompromised patients.


Assuntos
COVID-19 , Aranhas , Humanos , Animais , SARS-CoV-2 , Vacina de mRNA-1273 contra 2019-nCoV , Vacina BNT162 , COVID-19/prevenção & controle , Anticorpos Antivirais , Hospedeiro Imunocomprometido
2.
PLoS One ; 12(1): e0169593, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28072822

RESUMO

INTRODUCTION: Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose. METHODS: 314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800). BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability. RESULTS: Biases, limits of agreement (±1.96 SD) and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936) for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944) for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967) for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968) for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972) for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985) for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981) for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin. CONCLUSIONS: Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement.


Assuntos
Bicarbonatos/sangue , Glicemia , Estado Terminal , Eletrólitos/sangue , Hematócrito , Hemoglobinas , Sistemas Automatizados de Assistência Junto ao Leito , Idoso , Idoso de 80 Anos ou mais , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Gasometria/métodos , Gasometria/normas , Feminino , Hematócrito/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência
SELEÇÃO DE REFERÊNCIAS